| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability has been found in Edimax BR-6288ACL up to 1.12. Impacted is the function wiz_WISP24gmanual of the file wiz_WISP24gmanual.asp. Such manipulation of the argument manualssid leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor confirms that the affected product is end-of-life. They confirm that they "will issue a consolidated Security Advisory on our official support website." This vulnerability only affects products that are no longer supported by the maintainer. |
| A flaw has been found in Edimax BR-6258n up to 1.18. This issue affects the function formStaDrvSetup of the file /goform/formStaDrvSetup. This manipulation of the argument submit-url causes open redirect. The attack can be initiated remotely. The exploit has been published and may be used. The vendor confirms that the affected product is end-of-life. They confirm that they "will issue a consolidated Security Advisory on our official support website." This vulnerability only affects products that are no longer supported by the maintainer. |
| EDIMAX BR-6208AC V2_1.02 is vulnerable to Command Injection. This arises because the pppUserName field is directly passed to a shell command via the system() function without proper sanitization. An attacker can exploit this by injecting malicious commands into the pppUserName field, allowing arbitrary code execution. |
| Edimax IC-7100 does not properly neutralize requests. An attacker can create specially crafted requests to achieve remote code execution on the device |
| Edimax BR-6473AX v1.0.28 was discovered to contain a remote code execution (RCE) vulnerability via the Object parameter in the openwrt_getConfig function. |
| EDIMAX CV7428NS v1.20 was discovered to contain a remote code execution (RCE) vulnerability via the command parameter in the mp function. |
| A stack-based buffer overflow vulnerability in /bin/webs binary in Edimax BR6478AC V2 firmware veraion v1.23 allows attackers to overwrite other values located on the stack due to an incorrect use of the strcpy() function. |
| Edimax AC1200 Wi-Fi 5 Dual-Band Router BR-6476AC 1.06 suffers from Command Injection issues in /bin/goahead. Specifically, these issues can be triggered through /goform/tracerouteDiagnosis, /goform/pingDiagnosis, and /goform/fromSysToolPingCmd Each of these issues allows an attacker with access to the web interface to inject and execute arbitrary shell commands, with "root" privileges. |
| Edimax AC1200 Wi-Fi 5 Dual-Band Router BR-6476AC 1.06 is vulnerable to Buffer Overflow via /goform/fromSetLanDhcpsClientbinding. |
| Edimax AC1200 Wi-Fi 5 Dual-Band Router BR-6476AC 1.06 is vulnerable to Cross Site Scripting (XSS) in : /bin/goahead via /goform/setStaticRoute, /goform/fromSetFilterUrlFilter, and /goform/fromSetFilterClientFilter. |
| In Edimax AC1200 Wi-Fi 5 Dual-Band Router BR-6476AC 1.06, the request /goform/fromSetDDNS does not properly handle special characters in any of user provided parameters, allowing an attacker with access to the web interface to inject and execute arbitrary shell commands. |
| Edimax AC1200 Wi-Fi 5 Dual-Band Router BR-6476AC 1.06 is vulnerable to Buffer Overflow via /goform/getWifiBasic. |
| Edimax AC1200 Wave 2 Dual-Band Gigabit Router BR-6478AC V3 1.0.15 was discovered to contain a command injection vulnerability via fota_url in /boafrm/formLtefotaUpgradeQuectel |
| A vulnerability was found in Edimax BR-6288ACL 1.30. It has been declared as problematic. This vulnerability affects unknown code of the file wireless5g_basic.asp. The manipulation of the argument SSID leads to cross site scripting. The attack can be initiated remotely. The vendor was contacted early about this disclosure but did not respond in any way. |
| Edimax AC1200 Wave 2 Dual-Band Gigabit Router BR-6478AC V3 1.0.15 was discovered to contain a stack overflow vlunerability via peerPin parameter in the formWsc function. |
| Edimax AC1200 Wave 2 Dual-Band Gigabit Router BR-6478AC V3 1.0.15 was discovered to contain a command injection vulnerability via partition in /boafrm/formDiskFormat. |
| Edimax AC1200 Wave 2 Dual-Band Gigabit Router BR-6478AC V3_1.0.15 was discovered to contain a command injection vulnerability via the groupname at the /boafrm/formDiskCreateGroup. |
| Edimax AC1200 Wave 2 Dual-Band Gigabit Router BR-6478AC V3_1.0.15 was discovered to contain a command injection vulnerability via the foldername in /boafrm/formDiskCreateShare. |
| RE11S v1.11 was discovered to contain a stack overflow via the rootAPmac parameter in the formiNICbasicREP function. |
| The UPnP IGD implementation in Edimax EdiLinux on the Edimax BR-6104K with firmware before 3.25, Edimax 6114Wg, Canyon-Tech CN-WF512 with firmware 1.83, Canyon-Tech CN-WF514 with firmware 2.08, Sitecom WL-153 with firmware before 1.39, and Sweex LB000021 with firmware 3.15 allows remote attackers to execute arbitrary commands via shell metacharacters. |