Search Results (2168 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2023-53968 2 Db Elettronica, Dbbroadcast 3 Screen Sft Dab 600c, Sft Dab 600\/c, Sft Dab 600\/c Firmware 2025-12-26 9.8 Critical
Screen SFT DAB 600/C Firmware 1.9.3 contains a session management vulnerability that allows attackers to bypass authentication controls by exploiting IP address session binding. Attackers can reuse the same IP address and issue unauthorized requests to the userManager API to remove user accounts without proper authentication.
CVE-2023-53974 2 D-link, Dlink 3 Dsl-124, Dsl-124, Dsl-124 Firmware 2025-12-26 7.5 High
D-Link DSL-124 ME_1.00 contains a configuration file disclosure vulnerability that allows unauthenticated attackers to retrieve router settings through a POST request. Attackers can send a specific POST request to the router's configuration endpoint to download a complete backup file containing sensitive network credentials and system configurations.
CVE-2024-8074 2025-12-23 N/A
Missing Authentication for Critical Function, Missing Authorization vulnerability in Nomysoft Informatics Nomysem allows Collect Data as Provided by Users.This issue affects Nomysem: before 13.10.2024.
CVE-2024-24578 1 Raspberrymatic 1 Raspberrymatic 2025-12-23 10 Critical
RaspberryMatic is an open-source operating system for HomeMatic internet-of-things devices. RaspberryMatic / OCCU prior to version 3.75.6.20240316 contains a unauthenticated remote code execution (RCE) vulnerability, caused by multiple issues within the Java based `HMIPServer.jar` component. RaspberryMatric includes a Java based `HMIPServer`, that can be accessed through URLs starting with `/pages/jpages`. The `FirmwareController` class does however not perform any session id checks, thus this feature can be accessed without a valid session. Due to this issue, attackers can gain remote code execution as root user, allowing a full system compromise. Version 3.75.6.20240316 contains a patch.
CVE-2025-52692 1 Linksys 2 E9450-sg, E9450-sg Firmware 2025-12-23 8.8 High
Successful exploitation of the vulnerability could allow an attacker with local network access to send a specially crafted URL to access certain administration functions without login credentials.
CVE-2025-14567 2 Haxxorsid, Stock Management System Project 2 Stock-management-system, Stock Management System 2025-12-23 5.3 Medium
A weakness has been identified in haxxorsid Stock-Management-System up to fbbbf213e9c93b87183a3891f77e3cc7095f22b0. This affects an unknown function of the file /api/employees. Executing manipulation can lead to missing authentication. It is possible to launch the attack remotely. The exploit has been made available to the public and could be exploited. This product takes the approach of rolling releases to provide continious delivery. Therefore, version details for affected and updated releases are not available. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2025-3699 2025-12-23 9.8 Critical
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all versions, GB-50ADA-A all versions, GB-50ADA-J all versions, EB-50GU-A all versions, EB-50GU-J all versions, AE-200J all versions, AE-200A all versions, AE-200E all versions, AE-50J all versions, AE-50A all versions, AE-50E all versions, EW-50J all versions, EW-50A all versions, EW-50E all versions, TE-200A all versions, TE-50A all versions, TW-50A all versions, and CMS-RMD-J all versions allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information.
CVE-2025-7635 1 Calix 2 Calix Gigacenter Ont, Gigacenter Ont 2025-12-22 7.7 High
Unauthenticated Telnet access vulnerability in Calix GigaCenter ONT allows root access.This issue affects GigaCenter ONT: 844E, 844G, 844GE, 854GE.
CVE-2025-27019 2 Infinera, Nokia 3 Mtc-9, Infinera Mtc-9, Infinera Mtc-9 Firmware 2025-12-22 9.8 Critical
Remote shell service (RSH) in Infinera MTC-9 version R22.1.1.0275 allows an attacker to utilize password-less user accounts and obtain system access by activating a reverse shell.This issue affects MTC-9: from R22.1.1.0275 before R23.0.
CVE-2025-27020 2 Infinera, Nokia 3 Mtc-9, Infinera Mtc-9, Infinera Mtc-9 Firmware 2025-12-22 9.8 Critical
Improper configuration of the SSH service in Infinera MTC-9 allows an unauthenticated attacker to execute arbitrary commands and access data on file system . This issue affects MTC-9: from R22.1.1.0275 before R23.0.
CVE-2025-34073 2025-12-20 N/A
An unauthenticated command injection vulnerability exists in stamparm/maltrail (Maltrail) versions <=0.54. A remote attacker can execute arbitrary operating system commands via the username parameter in a POST request to the /login endpoint. This occurs due to unsafe handling of user-supplied input passed to subprocess.check_output() in core/http.py, allowing injection of shell metacharacters. Exploitation does not require authentication and commands are executed with the privileges of the Maltrail process.
CVE-2025-34434 1 Wwbn 1 Avideo 2025-12-19 9.1 Critical
AVideo versions prior to 20.1 with the ImageGallery plugin enabled is vulnerable to unauthenticated file upload and deletion. Plugin endpoints responsible for managing gallery images fail to enforce authentication checks and do not validate ownership, allowing unauthenticated attackers to upload or delete images associated with any image-based video.
CVE-2025-65010 2025-12-19 N/A
WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) is vulnerable to Broken Access Control in initial configuration wizard.cgi endpoint. Malicious attacker can change admin panel password without authorization. The vulnerability can also be exploited after the initial configuration has been set. The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable.
CVE-2025-65007 2025-12-19 N/A
In WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) due to lack of authentication in the configuration change module in the adm.cgi endpoint, the unauthenticated attacker can execute commands including backup creation, device restart and resetting the device to factory settings. The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable.
CVE-2023-4699 1 Mitsubishielectric 432 Fx3g-14mr\/ds, Fx3g-14mr\/ds Firmware, Fx3g-14mr\/es and 429 more 2025-12-16 10 Critical
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation MELSEC-F Series CPU modules, MELSEC iQ-F Series, MELSEC iQ-R series CPU modules, MELSEC iQ-R series, MELSEC iQ-L series, MELSEC Q series, MELSEC-L series, Mitsubishi Electric CNC M800V/M80V series, Mitsubishi Electric CNC M800/M80/E80 series and Mitsubishi Electric CNC M700V/M70V/E70 series allows a remote unauthenticated attacker to execute arbitrary commands by sending specific packets to the affected products. This could lead to disclose or tamper with information by reading or writing control programs, or cause a denial-of-service (DoS) condition on the products by resetting the memory contents of the products to factory settings or resetting the products remotely.
CVE-2023-34060 1 Vmware 2 Cloud Director, Photon Os 2025-12-16 9.8 Critical
VMware Cloud Director Appliance contains an authentication bypass vulnerability in case VMware Cloud Director Appliance was upgraded to 10.5 from an older version. On an upgraded version of VMware Cloud Director Appliance 10.5, a malicious actor with network access to the appliance can bypass login restrictions when authenticating on port 22 (ssh) or port 5480 (appliance management console) . This bypass is not present on port 443 (VCD provider and tenant login). On a new installation of VMware Cloud Director Appliance 10.5, the bypass is not present. VMware Cloud Director Appliance is impacted since it uses an affected version of sssd from the underlying Photon OS. The sssd issue is no longer present in versions of Photon OS that ship with sssd-2.8.1-11 or higher (Photon OS 3) or sssd-2.8.2-9 or higher (Photon OS 4 and 5).
CVE-2025-34068 2025-12-16 N/A
An unauthenticated remote command execution vulnerability exists in Samsung WLAN AP WEA453e firmware prior to version 5.2.4.T1 via improper input validation in the “Tech Support” diagnostic functionality. The command1 and command2 POST or GET parameters accept arbitrary shell commands that are executed with root privileges on the underlying operating system. An attacker can exploit this by crafting a request that injects shell commands to create output files in writable directories and then access their contents via the download endpoint. This flaw allows complete compromise of the device without authentication. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-04 UTC.
CVE-2025-59695 1 Entrust 11 Nshield 5c, Nshield 5c Firmware, Nshield Connect Xc and 8 more 2025-12-15 9.8 Critical
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a user with OS root access to alter firmware on the Chassis Management Board (without Authentication). This is called F04.
CVE-2025-34331 1 Audiocodes 3 Fax\/ivr, Fax Server, Interactive Voice Response 2025-12-12 7.5 High
AudioCodes Fax Server and Auto-Attendant IVR appliances versions up to and including 2.6.23 contain an unauthenticated file read vulnerability via the download.php script. The endpoint exposes a file download mechanism that lacks access control, allowing remote, unauthenticated users to request files stored on the appliance based solely on attacker-supplied path and filename parameters. While limited to specific file extensions permitted by the application logic, sensitive backup archives can be retrieved, exposing internal databases and credential hashes. Successful exploitation may lead to disclosure of administrative password hashes and other sensitive configuration data.
CVE-2025-67780 1 Spacex 1 Starlink Dish 2025-12-12 4.2 Medium
SpaceX Starlink Dish devices with firmware 2024.12.04.mr46620 (e.g., on Mini1_prod2) allow administrative actions via unauthenticated LAN gRPC requests, aka MARMALADE 2. The cross-origin policy can be bypassed by omitting a Referer header. In some cases, an attacker's ability to read tilt, rotation, and elevation data via gRPC can make it easier to infer the geographical location of the dish.