Export limit exceeded: 15406 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (15406 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-5685 1 Tenda 1 Cx12l 2026-04-07 8.8 High
A vulnerability was identified in Tenda CX12L 16.03.53.12. This affects the function fromAddressNat of the file /goform/addressNat. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit is publicly available and might be used.
CVE-2025-34106 2026-04-07 N/A
A buffer overflow vulnerability exists in PDF Shaper versions 3.5 and 3.6 when converting a crafted PDF file to an image using the 'Convert PDF to Image' functionality. An attacker can exploit this vulnerability by tricking a user into opening a maliciously crafted PDF file, leading to arbitrary code execution under the context of the user. This vulnerability has been verified on Windows XP, 7, 8, and 10 platforms using the PDFTools.exe component.
CVE-2025-34096 1 Efssoft 1 Easy File Sharing Web Server 2026-04-07 N/A
A stack-based buffer overflow vulnerability exists in Easy File Sharing HTTP Server version 7.2. The flaw is triggered when a crafted POST request is sent to the /sendemail.ghp endpoint containing an overly long Email parameter. The application fails to properly validate the length of this field, resulting in a memory corruption condition. An unauthenticated remote attacker can exploit this to execute arbitrary code with the privileges of the server process.
CVE-2020-36880 2 Flexense, Flexsense 2 Diskboss, Diskboss 2026-04-07 7.8 High
Flexsense DiskBoss 7.7.14 contains a local buffer overflow vulnerability in the 'Reports and Data Directory' field that allows an attacker to execute arbitrary code on the system.
CVE-2026-5684 1 Tenda 1 Cx12l 2026-04-07 8 High
A vulnerability was determined in Tenda CX12L 16.03.53.12. Affected by this issue is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. Executing a manipulation of the argument page can lead to stack-based buffer overflow. The attack requires access to the local network. The exploit has been publicly disclosed and may be utilized.
CVE-2026-5687 1 Tenda 1 Cx12l 2026-04-07 8.8 High
A weakness has been identified in Tenda CX12L 16.03.53.12. This issue affects the function fromNatStaticSetting of the file /goform/NatStaticSetting. This manipulation of the argument page causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made available to the public and could be used for attacks.
CVE-2026-5475 1 Nasa 1 Cfs 2026-04-07 5.5 Medium
A vulnerability was determined in NASA cFS up to 7.0.0. This impacts the function CFE_SB_TransmitMsg of the file cfe_sb_priv.c of the component CCSDS Header Size Handler. Executing a manipulation can lead to memory corruption. The project was informed of the problem early through an issue report but has not responded yet.
CVE-2026-5474 1 Nasa 1 Cfs 2026-04-07 6.3 Medium
A vulnerability was found in NASA cFS up to 7.0.0. This affects the function CFE_MSG_GetSize of the file apps/to_lab/fsw/src/to_lab_passthru_encode.c of the component CCSDS Packet Header Handler. Performing a manipulation results in heap-based buffer overflow. The attacker must have access to the local network to execute the attack. The project was informed of the problem early through an issue report but has not responded yet.
CVE-2026-5613 1 Belkin 2 F9k1015, F9k1015 Firmware 2026-04-07 8.8 High
A vulnerability was identified in Belkin F9K1015 1.00.10. This issue affects the function formReboot of the file /goform/formReboot. The manipulation of the argument webpage leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-5611 1 Belkin 2 F9k1015, F9k1015 Firmware 2026-04-07 8.8 High
A vulnerability was found in Belkin F9K1015 1.00.10. This affects the function formCrossBandSwitch of the file /goform/formCrossBandSwitch. Performing a manipulation of the argument webpage results in stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-5550 1 Tenda 2 Ac10, Ac10 Firmware 2026-04-07 8.8 High
A vulnerability was identified in Tenda AC10 16.03.10.10_multi_TDE01. This affects the function fromSysToolChangePwd of the file /bin/httpd. The manipulation leads to stack-based buffer overflow. The attack may be initiated remotely. Multiple endpoints might be affected.
CVE-2026-5567 1 Tenda 2 M3, M3 Firmware 2026-04-07 8.8 High
A flaw has been found in Tenda M3 1.0.0.10. This vulnerability affects the function setAdvPolicyData of the file /goform/setAdvPolicyData of the component Destination Handler. Executing a manipulation of the argument policyType can lead to buffer overflow. The attack can be executed remotely. The exploit has been published and may be used.
CVE-2026-5629 1 Belkin 2 F9k1015, F9k1015 Firmware 2026-04-07 8.8 High
A vulnerability was detected in Belkin F9K1015 1.00.10. The affected element is the function formSetFirewall of the file /goform/formSetFirewall. The manipulation of the argument webpage results in stack-based buffer overflow. The attack can be executed remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-5608 1 Belkin 2 F9k1122, F9k1122 Firmware 2026-04-07 8.8 High
A vulnerability was detected in Belkin F9K1122 1.00.33. Affected is the function formWlanSetup of the file /goform/formWlanSetup. The manipulation of the argument webpage results in stack-based buffer overflow. The attack may be performed from remote. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-5604 1 Tenda 2 Ch22, Ch22 Firmware 2026-04-07 8.8 High
A security flaw has been discovered in Tenda CH22 1.0.0.1. The impacted element is the function formCertLocalPrecreate of the file /goform/CertLocalPrecreate of the component Parameter Handler. Performing a manipulation of the argument standard results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks.
CVE-2026-5548 1 Tenda 2 Ac10, Ac10 Firmware 2026-04-07 8.8 High
A vulnerability was found in Tenda AC10 16.03.10.10_multi_TDE01. Affected by this vulnerability is the function fromSysToolChangePwd of the file /bin/httpd. Performing a manipulation of the argument sys.userpass results in stack-based buffer overflow. The attack can be initiated remotely.
CVE-2026-5612 1 Belkin 2 F9k1015, F9k1015 Firmware 2026-04-07 8.8 High
A vulnerability was determined in Belkin F9K1015 1.00.10. This vulnerability affects the function formWlEncrypt of the file /goform/formWlEncrypt. Executing a manipulation of the argument webpage can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-5609 1 Tenda 2 I12, I12 Firmware 2026-04-07 8.8 High
A flaw has been found in Tenda i12 1.0.0.11(3862). Affected by this vulnerability is the function formwrlSSIDset of the file /goform/wifiSSIDset of the component Parameter Handler. This manipulation of the argument index/wl_radio causes stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used.
CVE-2026-5614 1 Belkin 2 F9k1015, F9k1015 Firmware 2026-04-07 8.8 High
A security flaw has been discovered in Belkin F9K1015 1.00.10. Impacted is the function formSetPassword of the file /goform/formSetPassword. The manipulation of the argument webpage results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-5605 1 Tenda 2 Ch22, Ch22 Firmware 2026-04-07 8.8 High
A weakness has been identified in Tenda CH22 1.0.0.1. This affects the function formWrlExtraSet of the file /goform/WrlExtraSet. Executing a manipulation of the argument GO can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks.